Thermal Feasibility of Trombe Wall Utilization in a Model Building: Application of Trnsys Program - Raheleh Nowzari - Grāmatas - VDM Verlag Dr. Müller - 9783639339444 - 2011. gada 11. marts
Ja vāks un nosaukums nesakrīt, pareizs ir nosaukums

Thermal Feasibility of Trombe Wall Utilization in a Model Building: Application of Trnsys Program

Cena
€ 55,49

Pasūtīts no attālās noliktavas

Paredzamā piegāde . gada 8. - 22. sept.
Saņemiet paziņojumus par jauniem Raheleh Nowzari izdevumiem
Pievienot savam iMusic vēlmju sarakstam

Not rated yet

The objective of this study is to investigate the temperature behavior of a building integrated with a thermal storage wall and a window for direct solar gain for supplying heat in winter. This is achieved by modeling and simulation with the TRNSYS (Transient System Simulation) program. A hypothetical two story building with a total floor area of 120 meter square has been modeled with the program. A Trombe wall is used on the south façade of the ground floor. Additionally a direct gain window of area 6.5 meter square is placed on the south façade of the First floor. The hourly indoor temperature variations on the ground floor are compared with that of the First floor. It is assumed that the model building is located in Cyprus and Larnaca climatic conditions are used for simulation.

Mediji Grāmatas     Paperback Book   (Grāmata ar mīksto vāku un līmēto muguru)
Izlaists 2011. gada 11. marts
ISBN13 9783639339444
Izdevēji VDM Verlag Dr. Müller
Lapas 104
Izmēri 226 × 6 × 150 mm   ·   163 g
Valoda Angļu  

Vairāk no tā paša izdevēja