Performance of New and Aged Residential Fire Smoke Detectors - Nist - Grāmatas - Createspace - 9781496168689 - 2014. gada 7. marts
Ja vāks un nosaukums nesakrīt, pareizs ir nosaukums

Performance of New and Aged Residential Fire Smoke Detectors

Cena
€ 21,49

Pasūtīts no attālās noliktavas

Paredzamā piegāde . gada 8. - 22. okt.
Saņemiet paziņojumus par jauniem Nist izdevumiem
Pievienot savam iMusic vēlmju sarakstam

Not rated yet

Publisher Marketing: As part of the Consumer Product Safety Commission (CPSC) technical staff program to determine the effects of emissions from imported drywall on residential electrical, gas distribution, and fire safety components, the National Institute of Standards and Technology (NIST) has generated data to aid assessment of whether there has been a loss of functionality of fire smoke detectors exposed to those emissions. NIST tested four sets of smoke detectors in the Fire Emulator/Detector Evaluator (FEDE) and the UL 217 test apparatus. Set 1 (ionization only) detectors were provided by CPSC staff and described as having been installed in homes with imported drywall; Set 2 (ionization only) detectors (same models as Set 1 but different batches) were described as coming from contemporaneous homes without the presence of imported drywall; Set 3 smoke detectors were purchased new by NIST and tested as received; and Set 4 comprised detectors from Set 3 that had been subjected to an accelerated aging protocol to simulate 10-year exposure to the effluent from imported drywall. Detectors from Set 1 and Set 2 activated within UL 217 sensitivity test parameters. Tests using the FEDE found differences in sensitivity between Sets 1 and 2 and between the ionization detectors in Sets 3 and 4 that were numerically small compared to the allowable performance range. An even smaller improvement in sensitivity was found for photoelectric smoke detectors between Sets 3 and 4. Two of the Set 1 smoke detectors sensed the presence of smoke, but would not send the signal to activate interconnected alarms. Two other Set 1 smoke detectors failed to operate under AC power, but operated properly under the required 9V battery back-up. It could not be determined whether the observations of Set 1 detector performance could be attributed to exposure to the emissions from imported drywall or to other factors.

Mediji Grāmatas     Paperback Book   (Grāmata ar mīksto vāku un līmēto muguru)
Izlaists 2014. gada 7. marts
ISBN13 9781496168689
Izdevēji Createspace
Lapas 110
Izmēri 216 × 279 × 6 mm   ·   272 g

Vairāk no Nist

Rādīt visu

Skatīt visus Nist