This paper investigates the effect that the bulk lubricant concentration has on the non-adiabatic lubricant excess surface density on a roughened, horizontal flat pool-boiling surface. Both pool boiling heat transfer data and lubricant excess surface density data are given for pure R134a and three different mixtures of R134a and a polyolester lubricant (POE). A spectrofluorometer was used to measure the lubricant excess density that was established by the boiling of a R134a/POE lubricant mixture on a test surface. The lubricant is preferentially drawn out of the bulk refrigerant/lubricant mixture by the boiling process and accumulates on the surface in excess of the bulk concentration. The excess lubricant resides in an approximately 40 mm layer onthe surface and influences the boiling performance. The lubricant excess surface density measurements were used to modify an existing dimensionless excess surface density parameter so that it is valid for different reduced pressures. The dimensionless parameter is a key component for a refrigerant/lubricant pool boiling model given in the literature. In support of improving the boiling model, both the excess measurements and heat transfer data are provided for pure R134a and three R134a/lubricant mixtures at 277.6 K. The heat transfer data shows that the lubricant excess layer causes an average enhancement of the heat flux of approximately 50 % for the 0.5 % lubricant mass fraction mixture relative to pure R134a heat fluxes between 4 kW/m2 and 20 kW/m2. Conversely, both the 1 % and the 2 % lubricant mass fraction mixtures experienced an average degradation of approximately 60 % in the heat flux relative to pure R134a heat fluxes between approximately 4 kW/m2 and 20 kW/m2. This study is an effort toward generating data that can be used to support a boiling model that can be used to predict whether lubricants degrade or improve boiling performance.

Mediji Grāmatas     Paperback Book   (Grāmata ar mīksto vāku un līmēto muguru)
Izlaists 2013. gada 14. novembris
ISBN13 9781493768905
Izdevēji CreateSpace Independent Publishing Platf
Lapas 68
Izmēri 213 × 4 × 276 mm   ·   181 g
Valoda Angļu  

Vairāk no Nist

Rādīt visu

Skatīt visus Nist