Singlet Delta Oxygen: a Quantitative Analysis Using Off-axis Integrated-cavity-output-spectroscopy - Jeffrey E Gallagher - Grāmatas - Biblioscholar - 9781249600442 - 2012. gada 10. oktobris
Ja vāks un nosaukums nesakrīt, pareizs ir nosaukums

Singlet Delta Oxygen: a Quantitative Analysis Using Off-axis Integrated-cavity-output-spectroscopy


Saņemt e-pastu, kad prece būs pieejama
Do you have a profile? Pierakstīties
Pievienot savam iMusic vēlmju sarakstam

Publisher Marketing: A new spectroscopic technique applicable to the detection of ultra-weak and for- bidden molecular transitions is presented. The method is based on o -axis integrated- cavity-output spectroscopy (ICOS) and has been applied to the detection of singlet (a1 g) oxygen in the (1,0) band of the electric-quadrupole allowed Noxon system (b1 + g a1 g) of oxygen. The details of the method as well as spectroscopic data con rming the absolute line positions of twenty-one lines in the (1,0) band of the b1 + g a1 g have been completed to within 0:004 cm 1. A Boltzmann analysis veri ed previously calculated and unproven integrated cross sections for each of the lines. Ten lines were also pressure broadened from 25 Torr to 100 Torr, and pres- sure broadening coe cients were determined from -p = 3:61 10 6 cm 1=torr to 5:81 10 6 cm 1=torr. These coe cients illustrate that rotationally-inelastic colli- sions are the dominant mechanism in molecular pressure broadening. The singlet oxy- gen was generated in a microwave plasma and the afterglow passed through an o -axis ICOS measurement system consisting of an 82 cm long, high- nesse (F 248000) optical cavity. The mirror re-ectivity, R, was determined by performing a cavity- ringdown measurement and observing ringdown times of 220 s in a range from 1494 nm to 1512 nm.

Mediji Grāmatas     Paperback Book   (Grāmata ar mīksto vāku un līmēto muguru)
Izlaists 2012. gada 10. oktobris
ISBN13 9781249600442
Izdevēji Biblioscholar
Lapas 114
Izmēri 189 × 246 × 6 mm   ·   217 g

Mere med samme udgiver